Copper Wire Weight Calculator

Calculate copper wire weight from AWG gauge, length, and wire type for electrical installations.

O M T

Copper Wire Weight

Estimating copper wire weight helps electricians, engineers, and buyers plan material needs. Weight depends on wire diameter (AWG gauge), length, and copper density.

Weight Formula

$$\text{Weight} = \rho \times A \times L$$

For round wire:

$$A = \pi \left(\frac{D}{2}\right)^2$$

where:

  • \(\rho = 8.96\,\text{g/cm}^3\) — density of pure copper
  • \(D\) — wire diameter from the AWG table
  • \(L\) — wire length
  • \(A\) — cross-sectional area

Example: 4/0 AWG copper (0.46 in diameter) weighs about 0.646 lb per foot.

Frequently Asked Questions

How much does 12 AWG copper wire weigh per foot?

About 0.020 lb/ft (9 g/ft). Domestic wiring commonly uses 12 or 14 AWG copper.

What is the density of copper used in this calculator?

Pure copper at 8.96 g/cm³. Alloyed wire may weigh slightly differently.

How do I find wire diameter from AWG?

AWG uses a standardized diameter table. Higher gauge numbers mean thinner wire; 4/0 (0000) is the thickest common building wire.

How much does 4/0 copper wire weigh per foot?

About 0.646 lb/ft (293 g/ft) for solid pure copper at standard AWG diameter.

Is copper heavier than aluminum wire?

Yes. Copper is denser than aluminum, so equal-length wire of the same gauge weighs more but carries more current.